Buffer Overflow in Systerel S2OPC (CVE-2026-78049)
Summary
Vulnerability in Systerel S2OPC (CVE-2026-78049). Risk of unauthorized operations or information disclosure.
Original description
The description as published by the source.
A vulnerability has been found in Systerel S2OPC up to 1.7.3. Impacted is the function SOPC_NodeMgtHelperInternal_AddVariableNodeAttributes of the file src/ClientServer/address_space/internal/sopc_node_mgt_helper_internal.c of the component AddNodes Service. The manipulation of the argument UserAccessLevel leads to out-of-bounds read. It is possible to initiate the attack remotely. A high degree of complexity is needed for the attack. The exploitability is considered difficult. The exploit has been disclosed to the public and may be used. The identifier of the patch is aafbd37d381b618312ebdf5ddf57027f62c14fdd. It is suggested to install a patch to address this issue.
Source: NIST National Vulnerability Database NVD GitHub Advisory
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2026-78049 has been found in Systerel S2OPC.
Risk of unauthorized operations or information disclosure. CVSS score: 3.7/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Systerel S2OPC CVE-2026-78049" on the vendor's site.
CVE-2026-78049 (Systerel S2OPC) — CWE-119 / CVSS v3 3.7
Attack vector: remote (network-reachable) / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (CWE-119) exists in Systerel S2OPC.
Check the vendor advisory for the affected versions of Systerel S2OPC.
Severity: Low (CVSS 3.7/10). Risk of unauthorized operations or information disclosure.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで Systerel S2OPC を使っているサービスとバージョンを洗い出す。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。