Vulnerability in UltraVNC viewer (CVE-2026-7831)
Summary
Vulnerability in UltraVNC viewer (CVE-2026-7831). Risk of unauthorized operations or information disclosure.
Original description
The description as published by the source.
UltraVNC viewer through 1.8.2.2 contains an off-by-one stack buffer overflow in the RFB ServerInit message handler. In vncviewer/ClientConnection.cpp, when the server-supplied nameLength equals exactly 2024 the code declares a 2024-byte stack buffer _dn[2024] and calls ReadString(_dn, 2024). ReadString writes the NUL terminator at buf[length], i.e., _dn[2024], one byte past the end of the stack buffer. A malicious VNC server can trigger this condition by advertising a desktop name of length 2024 in its ServerInit message. On release builds without stack canaries the single-byte NUL overwrite adjacent stack data. On builds with /GS stack protection the canary is corrupted and the process terminates, resulting in denial of service. User interaction (connecting the viewer to the malicious server) is required.
Source: GitHub Security Advisories (Global) NVD GitHub Advisory
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2026-7831 has been found in UltraVNC viewer.
Risk of unauthorized operations or information disclosure. CVSS score: 7.6/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "UltraVNC viewer CVE-2026-7831" on the vendor's site.
CVE-2026-7831 (UltraVNC viewer) — CWE-193 / CVSS v3 7.6
Attack vector: remote (network-reachable) / unauthenticated
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
A vulnerability (CWE-193) exists in UltraVNC viewer.
Check the vendor advisory for the affected versions of UltraVNC viewer.
Severity: High (CVSS 7.6/10). Risk of unauthorized operations or information disclosure.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで UltraVNC viewer を使っているサービスとバージョンを洗い出す。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。