OS Command Injection in Lantronix SLC8000 before firmware (CVE-2026-80152)
Summary
OS command injection in Lantronix SLC8000 before firmware (CVE-2026-80152). Successful exploitation can lead to full system takeover.
Original description
The description as published by the source.
Lantronix SLC8000 before firmware v9.7.0.3, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers with the services permission to execute arbitrary shell commands as root by exploiting the set script schedule command that passes unsanitized user input to a system() call. Attackers with the services permission can authenticate to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-attached devices.
Source: NIST National Vulnerability Database NVD GitHub Advisory
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2026-80152 has been found in Lantronix SLC8000 before firmware.
Successful exploitation can lead to full system takeover. CVSS score: 9.1/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Lantronix SLC8000 before firmware CVE-2026-80152" on the vendor's site.
CVE-2026-80152 (Lantronix SLC8000 before firmware) — CWE-78 / CVSS v3 9.1
Attack vector: remote (network-reachable) / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
OS command injection (CWE-78) exists in Lantronix SLC8000 before firmware.
Check the vendor advisory for the affected versions of Lantronix SLC8000 before firmware.
Severity: Critical (CVSS 9.1/10). Successful exploitation can lead to full system takeover.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで Lantronix SLC8000 before firmware を使っているサービスとバージョンを洗い出す。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。