OS Command Injection in iot-embedded (CVE-2026-8153)
Summary
OS command injection in iot-embedded (CVE-2026-8153). Successful exploitation can lead to full system takeover.
Original description
The description as published by the source.
OS command injection in Dashboard Server interface in Universal Robots PolyScope versions prior to 5.21.1 allows unauthenticated attacker to craft commands that will execute code on the robot's OS.
Source: NIST National Vulnerability Database NVD GitHub Advisory
AI summary
Written by an external AI model and may contain mistakes. Check the original description and references below before acting on it.
A vulnerability in Universal Robots' PolyScope allows unauthorized remote control of robots, posing the risk of unauthorized parties controlling the robots and causing malfunctions. Industries using robots, like manufacturing, need to update their systems quickly.
Universal Robots PolyScope's Dashboard Server interface, allowing remote control via a TCP/IP socket, contains an OS command injection vulnerability that lets attackers execute code on the OS without authentication. Versions affected are prior to 5.21.1, with the issue being patched in 5.21.1. The exploit is critical due to its remote executability and lack of user interaction requirement.
OS command injection in Universal Robots PolyScope's Dashboard Server interface.
Remote control via GUI on a TCP/IP socket (port 29999).
Critical (CVSS v3: 9.8) due to unauthenticated remote code execution.
Upgrade to PolyScope version 5.21.1 or later.
None specified as immediate patching is required.
Monitor for unauthorized commands on TCP connections to port 29999.
Related past incidents Similar incidents extracted from past CVEs
Similar OS command injection vulnerability in IoT device management software.
Dashboard server vulnerability in industrial robot's UI, leading to remote code execution.
Exploited IoT device vulnerabilities for launching DDoS attacks.
If this happens at your company Expected impact per business scenario
An attacker gains control over production line robots, causing operational interruption and potential safety hazards.
Remote control of robots leading to mishandling of goods or disruption of logistics operations.
Robot malfunction in sensitive environments such as hospitals, leading to safety risks to patients.
Organizations should urgently update PolyScope to version 5.21.1 or later to mitigate the risk of remote code execution on their robots.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.依存マニフェストで影響コンポーネントを特定する。
-
7Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番では Step 3 と同じログクエリでアラート再発が無いか継続監視。
References
- web universal-robots.com
- web nvd.nist.gov
- web universal-robots.com
- web github.com