The affected code used child_process.execSync with a shell string for generator installation and...
Summary
OS command injection reported (CVE-2026-89116). Confidential information can be exposed externally.
Original description
The description as published by the source.
The affected code used child_process.execSync with a shell string for generator installation and uninstallation. This allowed an attacker to execute arbitrary OS commands with the developer's privileges by manipulating the ApplicationWizard.installationLocation VS Code workspace configuration value. Because the value was passed directly to the shell without sanitisation, a malicious workspace repository could craft a settings.json that injects OS commands when a developer opens the project and triggers a generator installation.
Source: NIST National Vulnerability Database NVD GitHub Advisory
Auto-generated summary
Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.
A vulnerability tracked as CVE-2026-89116 has been found.
Confidential information can be exposed externally. CVSS score: 5.9/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "CVE-2026-89116" on the vendor's site.
CVE-2026-89116 — CWE-78 / CVSS v3 5.9
Attack vector: remote (network-reachable) / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.
OS command injection (CWE-78) has been reported.
Check the vendor advisory for the affected versions.
Severity: Medium (CVSS 5.9/10). Confidential information can be exposed externally.
Update to the patched release per vendor advisory.
Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.
Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.
Response actions
Concrete steps and command examples for SOC/SRE teams to execute in order
-
1Identify exposure identify
Audit SBOM/dependencies for affected components.資産台帳・SBOM・依存マニフェストで影響コンポーネントを特定する。
-
2Post-deployment verification verify
Confirm patched version is live in productionパッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。
References
- web cna@sap.com
- web cna@sap.com
- web nvd.nist.gov