Categories
CVE-2026-93338 medium CVSS 5.3

Vulnerability in Grandstream GWN7660ELR before firmware (CVE-2026-93338)

Summary

Vulnerability in Grandstream GWN7660ELR before firmware (CVE-2026-93338). Risk of unauthorized operations or information disclosure.

Original description

The description as published by the source.

Grandstream GWN7660ELR before firmware version 1.0.27.6 contains an information disclosure vulnerability that allows unauthenticated remote attackers to obtain sensitive system information by querying the SNMP v2c service configured with the default community string 'public'. Attackers can query standard MIBs over the SNMP port to retrieve operating system and kernel version, running process names and command-line arguments, network interface configuration, routing table entries, ARP table mappings, active TCP connection details, and file system paths, enabling detailed reconnaissance of the device and adjacent network infrastructure.

Source: NIST National Vulnerability Database NVD GitHub Advisory

Auto-generated summary

Assembled by SecPulse from the source data (CVSS, CWE, affected versions) using templates — no AI involved. Check the original description and references below for exact details.

A vulnerability tracked as CVE-2026-93338 has been found in Grandstream GWN7660ELR before firmware.
Risk of unauthorized operations or information disclosure. CVSS score: 5.3/10.
What to do: apply the vendor's official patched release.
If unsure, ask your IT team or search "Grandstream GWN7660ELR before firmware CVE-2026-93338" on the vendor's site.

CVE-2026-93338 (Grandstream GWN7660ELR before firmware) — CWE-1188 / CVSS v3 5.3
Attack vector: remote (network-reachable) / unauthenticated / no user interaction
Plan: 1) Audit SBOM/dependencies, 2) Stage→prod upgrade, 3) Add WAF/proxy monitoring on affected endpoints, 4) Hunt IOCs in logs.
Refs: see the GHSA / vendor advisory / patched release linked on this page.

❓ What is the problem

A vulnerability (CWE-1188) exists in Grandstream GWN7660ELR before firmware.

📍 Affected scope

Check the vendor advisory for the affected versions of Grandstream GWN7660ELR before firmware.

🔥 Severity

Severity: Medium (CVSS 5.3/10). Risk of unauthorized operations or information disclosure.

🔧 How to fix

Update to the patched release per vendor advisory.

🛡️ Workaround

Until the patch is applied: disable the affected feature, apply WAF rules, or restrict access via network ACLs.

🔍 Detection

Search webserver/proxy logs for unusual request patterns matching this CVE's known IOCs. Audit SBOM/dependencies to find affected services.

Response actions

Concrete steps and command examples for SOC/SRE teams to execute in order

  1. 1
    Identify exposure identify
    Audit SBOM/dependencies for affected components.

    資産台帳・SBOM・依存マニフェストで Grandstream GWN7660ELR before firmware を使っているサービスとバージョンを洗い出す。

  2. 2
    Post-deployment verification verify
    Confirm patched version is live in production

    パッチ適用後、ステージングで PoC または同等の悪用パターンを再現して脆弱性が閉じたことを確認。本番ではアクセスログ・WAF でアラート再発が無いか継続監視。

References

We use cookies for analytics and ad measurement. This setting applies to all Game co., Ltd. sites. Details